Drop files here

SQL upload ( 0 ) x -

Page-related settings Click on the bar to scroll to top of page
Press Ctrl+Enter to execute query Press Enter to execute query
ascending
descending
Order:
Debug SQL
Count
Execution order
Time taken
Order by:
Group queries
Ungroup queries
Collapse Expand Show trace Hide trace Count : Time taken :
Bookmarks
Refresh
Add
No bookmarks
Add bookmark
Options
Set default





Collapse Expand Requery Edit Explain Profiling Bookmark Query failed Database : Queried time :
Browse mode
Customize browse mode.
Browse mode
Documentation Use only icons, only text or both. Restore default value
Documentation Use only icons, only text or both. Restore default value
Documentation Whether a user should be displayed a "show all (rows)" button. Restore default value
Documentation Number of rows displayed when browsing a result set. If the result set contains more rows, "Previous" and "Next" links will be shown. Restore default value
Documentation SMART - i.e. descending order for columns of type TIME, DATE, DATETIME and TIMESTAMP, ascending order otherwise. Restore default value
Documentation Highlight row pointed by the mouse cursor. Restore default value
Documentation Highlight selected rows. Restore default value
Documentation Restore default value
Documentation Restore default value
Documentation Repeat the headers every X cells, 0 deactivates this feature. Restore default value
Documentation Maximum number of characters shown in any non-numeric column on browse view. Restore default value
Documentation These are Edit, Copy and Delete links. Restore default value
Documentation Whether to show row links even in the absence of a unique key. Restore default value
Documentation Default sort order for tables with a primary key. Restore default value
Documentation When browsing tables, the sorting of each table is remembered. Restore default value
Documentation For display Options Restore default value
SELECT * FROM `fault_codes`
Edit inline ] [ Edit ] [ Explain SQL ] [ Create PHP code ] [ Refresh ]
Full texts id code brand description cause solutions
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 1
1 P0001 Generico Circuito Regulador Volume Combustivel Aberto Circuito aberto no controlo do regulador de volume... Verificar cablagem e conexoes do regulador de volu...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 2
2 P0002 Generico Circuito Regulador Volume Combustivel - Fora de Es... Regulador de volume de combustivel a funcionar for... Verificar pressao de combustivel
Inspecionar regul...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 3
3 P0003 Generico Circuito Regulador Volume Combustivel - Tensao Bai... Tensao baixa no circuito de controlo do regulador ... Verificar curto-circuito para massa na cablagem
Te...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 4
4 P0004 Generico Circuito Regulador Volume Combustivel - Tensao Alt... Tensao alta no circuito de controlo do regulador d... Verificar curto-circuito para positivo na cablagem...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 5
5 P0010 Generico Circuito Atuador Posicao Comando Valvulas A (Banco... Circuito aberto ou curto no atuador da posicao da ... Verificar solenoide do atuador da arvore de cames
...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 6
6 P0011 Generico Posicao Comando Valvulas A - Avanco Excessivo ou P... Sincronizacao da arvore de cames com avanco excess... Verificar nivel e qualidade do oleo do motor
Inspe...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 7
7 P0012 Generico Posicao Comando Valvulas A - Atraso Excessivo (Ban... Sincronizacao da arvore de cames com atraso excess... Verificar nivel e qualidade do oleo do motor
Inspe...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 8
8 P0013 Generico Circuito Atuador Posicao Comando Valvulas B (Banco... Circuito aberto ou curto no atuador da arvore de c... Verificar solenoide do atuador da arvore de cames ...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 9
9 P0014 Generico Posicao Comando Valvulas B - Avanco Excessivo ou P... Sincronizacao da arvore de cames de escape com ava... Verificar nivel e qualidade do oleo do motor
Inspe...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 10
10 P0016 Generico Correlacao Posicao Cigoeiral - Arvore Cames (Banco... Erro de correlacao entre sensores de posicao do ci... Verificar corrente/distribuicao por desgaste ou sa...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 11
11 P0017 Generico Correlacao Posicao Cigoeiral - Arvore Cames (Banco... Erro de correlacao entre sensores de posicao do ci... Verificar corrente/distribuicao por desgaste ou sa...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 12
12 P0030 Generico Circuito Aquecedor Sonda Lambda (Banco 1 Sensor 1) Avaria no circuito do aquecedor da sonda lambda Verificar resistencia do aquecedor da sonda lambda...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 13
13 P0031 Generico Circuito Aquecedor Sonda Lambda - Tensao Baixa (Ba... Tensao baixa no circuito do aquecedor da sonda lam... Verificar curto-circuito para massa no circuito do...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 14
14 P0032 Generico Circuito Aquecedor Sonda Lambda - Tensao Alta (Ban... Tensao alta no circuito do aquecedor da sonda lamb... Verificar curto-circuito para positivo no circuito...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 15
15 P0036 Generico Circuito Aquecedor Sonda Lambda (Banco 1 Sensor 2) Avaria no circuito do aquecedor da sonda lambda (p... Verificar resistencia do aquecedor da sonda lambda...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 16
16 P0100 Generico Circuito Medidor Massa/Volume de Ar Avaria no circuito do sensor MAF Verificar conector do sensor MAF
Inspecionar admis...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 17
17 P0101 Generico Circuito Medidor Massa/Volume de Ar - Fora de Espe... Problema de funcionamento do sensor MAF Limpar sensor MAF com produto adequado
Verificar f...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 18
18 P0102 Generico Circuito Medidor Massa/Volume de Ar - Sinal Baixo Sinal baixo do sensor MAF Verificar cablagem do sensor MAF por curtos
Inspec...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 19
19 P0103 Generico Circuito Medidor Massa/Volume de Ar - Sinal Alto Sinal alto do sensor MAF Verificar curto-circuito para positivo na cablagem...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 20
20 P0104 Generico Circuito Medidor Massa/Volume de Ar - Intermitente Sinal intermitente do sensor MAF Verificar cablagem por curtos ou circuitos abertos...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 21
21 P0105 Generico Circuito Pressao Absoluta Coletor/Pressao Barometr... Avaria no circuito do sensor MAP Verificar conector do sensor MAP
Inspecionar mangu...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 22
22 P0106 Generico Circuito Pressao Absoluta Coletor/Pressao Barometr... Problema de funcionamento do sensor MAP Verificar fugas de vacuo
Inspecionar sensor MAP
Ve...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 23
23 P0107 Generico Circuito Pressao Absoluta Coletor - Sinal Baixo Sinal baixo do sensor MAP Verificar curto-circuito para massa na cablagem
In...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 24
24 P0108 Generico Circuito Pressao Absoluta Coletor - Sinal Alto Sinal alto do sensor MAP Verificar curto-circuito para positivo na cablagem...
Edit Edit Copy Copy Delete Delete
DELETE FROM fault_codes WHERE `fault_codes`.`id` = 25
25 P0110 Generico Circuito Temperatura Ar Admissao Avaria no circuito do sensor IAT Verificar conector do sensor IAT
Inspecionar cabla...
With selected: With selected:
Query results operations Copy to clipboard Copy to clipboard Export Export Display chart Display chart Create view Create view
Bookmark this SQL query Bookmark this SQL query